Electromechanical cylinder lock with a built-in access controller. Possible to connect the "exit" button and readers using the Wiegand 26,Wiegand 34, Wiegand 42 or 1-Ware.

Advantages

  • Electromechanical cylinder lock
  • Electromechanical lock of lock`s bolt
  • Electromechanical Latch Control
    — Control mode: manual or automatic
  • Power and temperature control
  • Configurable lock response to power failure
  • Independent programming of lock`s functions
  • Information outputs on the position of the crossbars and the state of the latch
  • Low power consumption
  • Convenience of installation and operation

Description

Designed for installation in metal doors.

Open/close the lock - mechanically, locking/unlocking - electronically.

Equipment

  • Lock with integrated access controller
  • Power supply with built-in battery
  • Lock / unlock button inside the room
  • Invoice / mortise reader and electronic keys

Functionality

  1. Deadbolt lock
    The electromechanical device of the lock allows you to lock the lock bolts in the fully extended state.
  2. Electromechanical lock latch control
    Disconnecting the latch from the door handle using an electronic key or the "exit" button
  3. Changable lock`s modes
    Configurable latch and bolt control mode: select manual or automatic lock.
  4. Sound indication of lock / unlock lock
    Information output about the position of the crossbars. It can be used to remove information about the status of the lock by security systems and to connect the reader indication in the locked position.
  5. Voltage
    The lock can be connected to a voltage source from 10 V to 16 V. DC voltage - 12 volts. When the supply voltage is below 10 V, the device automatically unlocks (this function is not configured and does not turn off). The current strength is greater than or equal to 300 mA.
  6. Temperature control
    When the air temperature inside the castle drops below +10 C, the heating of the electromechanical part of the castle is automatically turned on. In this case, the current does not exceed 160 mA/
  7. Unlocking the lock during a power failure (the function is enabled by default)
    Customizable lock response to lack power. In the event of a power failure, the device will automatically unlock or remain unchanged.
  8. Factory setting
    Not a single electronic key is registered in the lock memory.
    Power Break Unlock - On.
    Auto Lock - Of.
    Manual Lock - On.


Specifications

Class (GOST 5089-2011) 4
Type of Installation Mortise
Door Leaf Thickness 50-85 mm
Sizes 203х129х32 mm
Weight 2,8 kg
Bolt Overhang 30 mm
Bolt Diameter 18 mm

See also